Configuration sFLOW onDELL PC 6248
Use https://seceonhelp.freshdesk.com/support/login to access updated Knowledge Base Articles, Submit Technical Support Tickets and Review Status of submitted support tickets.
Configuration sFLOW onDELL PC 6248
The following commands configure a Dell PowerConnect 6248 series switch (10.0.0.250), sampling packets at 1-in-512, polling counters every 30 seconds and sending sFlow to an analyzer (10.0.0.50) over UDP using the default sFlow port (6343):sflow 1 destination 10.0.0.50 owner 1 timeout 4294967295
sflow 1 polling ethernet 1/g1-1/g10 30
sflow 1 sampling ethernet 1/g1-1/g10 512
exit