Conguration of sflow from Dell Force10

Use https://seceonhelp.freshdesk.com/support/login to access updated Knowledge Base Articles, Submit Technical Support Tickets and Review Status of submitted support tickets.

Conguration of sflow from Dell Force10

The following commands configure a Force10 switch (10.0.0.245), sampling packets at 1-in-512, polling counters every 30 seconds and sending the sFlow to the CCE (10.0.0.50) which acts as an sFlow collector over UDP using the default sFlow port (6343):

config> sflow collector 10.0.0.50 agent-addr 10.0.0.245 config> sflow sample-rate 512 config> sflow polling 30 config> sflow enable

Then for each interface:

interface> sflow enable

You can also use the following command to list the configuration settings:

show sflow 