Windows AD+FTP nxlog Configuration

NXLOG is used to process the collected information and send it on to the OTM CCE.

  • Login on FTP server.

  • Download the latest version of nxlog. It is easiest to choose the Windows msi file which includes an installer. Use the link below:

http://nxlog.org/products/nxlog-community-edition/download   

  • Open the Nxlog configuration file at:

        C:\Program Files (x86)\nxlog\conf\nxlog.conf

Replace the entire configuration file by pasting the following Below – Note to replace the variable (IP Address of Seceon Collector) with the actual Seceon Server IP address:

## This is a sample configuration file. See the nxlog reference manual about the ## configuration options. It should be installed locally and is also available ## online at http://nxlog.org/docs/ ## Please set the ROOT to the folder your nxlog was installed into, ## otherwise it will not start. define ROOT C:\Program Files\nxlog #define ROOT C:\Program Files (x86)\nxlog Moduledir %ROOT%\modules CacheDir %ROOT%\data Pidfile %ROOT%\data\nxlog.pid SpoolDir %ROOT%\data LogFile %ROOT%\data\nxlog.log <Extension _json> Module xm_json </Extension> define aisiem \ 1, 3, 4, 5, 6, 7, 8, 9, 10, 12, 13, 14, 15, 17, 18,19, 20, 21, 104, 258, 259, 260, \ 261, 262, 500, 517, 520, 528, 529, 530, 531, 532, 533, 534, 535, 536, 537, 538, 539,\ 540, 551, 552, 565, 600, 608, 609, 621, 622, 626, 627, 628, 629, 630, 636, 642, 644,\ 645, 647, 632, 663, 664, 671, 673, 675, 676, 677, 679, 680, 681, 682, 683, 684, 689,\ 690, 692, 1001, 1006, 1007, 1008, 1015, 1102, 1116, 1117, 1118, 1119, 2003, 2100, \ 7034, 4624, 4625, 4634, 4647, 4649, 4656, 4657, 4659, 4661, 4663, 4670, 4688, 4697, \ 4704, 4705, 4717, 4718, 4720, 4722, 4723, 4724, 4725, 4726, 4727, 4728, 4729, 4730, \ 4731, 4732, 4733, 4734, 4735, 4737, 4738, 4739, 4740, 4741, 4742, 4743, 4744, 4745, \ 4746, 4747, 4748, 4749, 4750, 4751, 4752, 4753, 4754, 4755, 4756, 4757, 4758, 4759, \ 4760, 4761, 4762, 4763, 4764, 4767, 4769, 4771, 4772, 4773, 4775, 4776, 4777, 4778, \ 4779, 4780, 4782, 4783, 4784, 4785, 4786, 4787, 4788, 4789, 4790, 4791, 4793, 4794, \ 4797, 4798, 4800, 4801, 4802, 4803, 5001, 5004, 5007, 5010, 5012, 5136, 5137, 5140, \ 5141, 5142, 5143, 5144, 5145, 5376, 5377, 7045, 8003, 8004, 8007, 64004 <Extension syslog> Module xm_syslog </Extension> <Input in> Module im_msvistalog Query <QueryList>\ <Query Id="0">\ <Select Path="Security">* </Select>\ <Select Path="Application">* </Select>\ <Select Path="Setup">* </Select>\ <Select Path="System">* </Select>\ </Query>\ </QueryList> <Exec> if ($EventID NOT IN (%aisiem%)) drop(); </Exec> </Input> <Input FTP_In> Module im_file File "C:\Program Files (x86)\Ipswitch\WS_FTP Server\Logging Server\Logs*" SavePos TRUE InputType LineBased Exec if $raw_event =~ /^#/ drop(); Exec $Message = $raw_event; </Input> <Output out> Module om_udp Host CCE_IP_ADDRESS Port 5154 Exec to_json(); </Output> <Output FTP_Out> Module om_udp Host CCE_IP_ADDRESS Port 514 Exec $SyslogFacilityValue = 2; Exec $SourceName = 'windows_ftp_logs'; Exec to_syslog_bsd(); </Output> <Route 1> Path in => out </Route> <Route FTP> Path FTP_In => FTP_Out </Route>

Note . 1 For Windows Events

  • Restart nxlog from services or type the following at an elevated command prompt: 

 net stop nxlog

 net start nxlog

 