Configuring the sFlow Collector
Choose the menu MAINTENANCE > sFlow > sFlow Collector to load the following page.
Figure 2-2Configuring the sFlow Collector
Follow these steps to configure the sFlow Collector:
1)Select a Collector and configure the relevant parameters.
Collector ID | Displays the Collector ID. The switch supports 4 collectors at most. |
Description | Give the collector a description for identification with 16 characters at most. |
Collector IP | Enter the IP address of the host that runs the sFlow Collector. |
Collector Port | Specify the UDP port number for the sFlow collector. The default is port 6343. |
Maximum Datagram Size | Specify the maximum number of data bytes that can be sent in a single sample datagram. Valid values are from 300 to 1400 bytes and the default is 300 bytes. |
Timeout (s) | Specify the aging time after which the sFlow Collector will become invalid. Valid values are from 0 to 2000000 seconds; the default is 0, which means the collector is always valid. |
Lifetime (s) | Displays the remaining time of the collector. Lifetime counts down from Timeout. |
2)Click Apply.