Overview

We are providing you the steps to integrate your Vmware Esxi/Vsphere with Seceon SIEM so that you can have Comprehensive visibility and Proactive Threat Detection in your Environment. There will be a log transfer between your firewall to CCE (Collection and Control Engine ). In this document, we are guiding you through the steps for Netflows and Syslog forwarding.

Procedure :


  1. From the object navigator select “Esxi host” that you want to configure and click the “Manage” tab.

...

5.The format is tcp|udp|ssl://log_insight-host:514|1514, where log_insight-hostis the IP address or host name of the Log Insight virtual appliance. Next steps to be followed are:

      NOTE : Use port 514 for UDP and TCP communication, and port 1514 for SSL protocol. 

...

                           5.  Click OK


VERIFICATION OF CONFIGURATION

Verification can be done either from CCE Server or from UI.

Using UI

STEP 1: Log in to UI >> SYSTEM

Image Added

STEP 2: >> LOGS AND FLOWS COLLECTION STATUS.


Image Added


STEP 3: >>Inside SOURCE DEVICE IP, IP will reflect.

Image Added

Using CCE SERVER

sudo tcpdump -i any host 514 (for logs) and 9995 (for flows) and host <IP address> -AAA” command should be running on the CCE server to check whether or not we are getting logs.